2026 · 04 · 12

Walden microhydro install — 1.8 kW Pelton on a 220-foot head

Off-grid retrofit on a 1968 hill farm without grid service. Replaced a worn-out 6 kW genset with a continuous-baseload Pelton runner cut from the brook above the house, paired with 14 kWh LFP and a 4.4 kW Outback Radian inverter.

J-05 / HYDRO · 14 days on site · 38.2 hrs labor · LFP 14 kWh · Outback Radian 4.4 kW · Walden, VT

2026 · 02 · 20

Cabot Hill knob-and-tube remediation

1851 cape-style farmhouse, six previous re-feeds. Pulled NM-B through plaster cavities without opening more than the closet back; AFCI changeout on a Square D QO-Plug-on-Neutral; three two-way switches restored to function.

J-04 / HERITAGE · 18 days on site · 142 hrs labor · 1 panel · 14 circuits · Cabot, VT

2025 · 11 · 04

East Craftsbury sugarhouse evaporator wiring

New 4×14 oil-fired evaporator on an existing sugarhouse. Three-phase 240V to vacuum, hood fans, RO booster, head-tank float, perimeter heat-trace. 1,800 taps growing to 3,500 over two seasons.

J-03 / SUGAR · 9 days on site · 64 hrs labor · 6 motor circuits · East Craftsbury, VT

2025 · 09 · 18

Greensboro Bend dairy panel rebuild

52-cow tie-stall barn. 320A meter base & main, equipotential plane re-bonded, milk-house GFCI to NEC 547. Stray-voltage baseline at 0.18 V before; 0.09 V after.

J-02 / DAIRY · 11 days on site · 96 hrs labor · NEC 547 · GMP coordination · Greensboro Bend, VT


Older entries are archived in the shop. We can pull a specific job if you ask — every invoice we've written since 2014 is in a binder on the shelf above Marya's desk.

References & sources

  1. NEC Article 547. up.codes.
  2. NEC Article 250, grounding. up.codes.
  3. UW Dairy Stray Voltage Program. uwm.edu.
  4. VT Division of Fire Safety. firesafety.vermont.gov.
  5. UVM Maple Research Center. uvm.edu.
  6. U.S. DOE on microhydro. energy.gov.